1. Measure Finished-to-Finished
Always include finished flooring thickness on both landings when measuring Total Rise. Even a 3/4" hardwood floor added later can trigger an IRC 3/8" riser variance failure.
THE TOOLBOX / CARPENTRY & CONSTRUCTION
Compute exact stair riser height to the nearest 1/16 inch, total run, bottom riser drop cut, 2×12 stringer length, throat depth, and IRC R311.7 headroom compliance.
CARPENTRY & CODE REFERENCE
Always include finished flooring thickness on both landings when measuring Total Rise. Even a 3/4" hardwood floor added later can trigger an IRC 3/8" riser variance failure.
Well-proportioned stairs satisfy 2 × Riser + Tread = 24" to 25" with a slope between 30° and 37°. Steeper stairs feel cramped; shallower stairs disrupt natural stride rhythm.
After laying out all steps on your 2×12 with stair gauges on your framing square, rip the exact tread thickness off the bottom plumb line so Step #1 matches Steps #2–N.
Check fractions in Fraction to Decimal Chart, estimate lumber in Board Feet Calculator, or figure footings in Concrete Calculator.
Measure the exact vertical Total Rise from finished lower floor to finished upper floor. Divide Total Rise by your target riser height (typically 7" to 7.5") and round to a whole number of risers. Divide Total Rise by that riser count for the exact cut riser height, then multiply the number of treads by your tread depth (10"–11") for Total Run.
Every step receives a tread board on top, which raises the walking surface by the tread thickness—except the floor at the bottom. Subtracting one tread thickness (e.g., 1" interior or 1.5" deck board) from the bottom of the stringer keeps the first step identical in height to all upper steps.
Under IRC R311.7, maximum riser height is 7-3/4 inches (7.75"), minimum tread depth is 10 inches, minimum clear width is 36 inches, minimum headroom clearance is 6 ft 8 in (80 inches), and the greatest riser variance cannot exceed 3/8 inch.
After cutting the triangular step notches into a 2×12 (11.25" actual width), leave at least 3.5 inches (5 inches preferred for exterior decks) of solid uncut lumber along the bottom edge so the stringer does not crack under load.