Header Size Calculator —
Door & Window Header Depth, Jack Studs & Cut Length Estimator.

Estimate residential door and window header sizes (2×6 through LVL), required jack studs per side, and exact header cut lengths for exterior load-bearing, interior bearing, and non-bearing walls.

Openings:
Recommended Header & StudsCut Length: 75.0"
(2) 2×10
Jack Studs
1 / side
2 total trimmers
King Studs
1 / side
Full wall height
Header Cut
75"
RO + jacks
HEADER: (2) 2×10Rough Opening: 6.0 ft (72")KingJack(s)

Estimated per IRC R602.7 guidelines for 28 ft building width & 30 psf snow load. Always confirm final beam sizing against your local building department’s adopted IRC edition or a licensed structural engineer.

FRAMING & SPAN TOOLS

Header Framing Tips & Related Structural Calculators.

1. Remember ½" Plywood Spacer for 2×4 Walls

Two 2× dimensional boards measure 3.0" thick, while a standard 2×4 wall is 3.5" wide. Sandwich a ½" OSB or plywood spacer between the two header plies (or rigid foam in cold climates) so the header sits flush with both drywall faces.

Frequently Asked Questions

What size header do I need for a 6-foot load-bearing opening?

In a standard 28-foot-wide home supporting roof and ceiling loads only (30 psf snow load) using #2 Douglas Fir or Southern Pine, a 6-foot exterior opening typically requires a (2) 2×10 header with 1 jack stud per side. If the wall also supports a second floor above, upgrade to (2) 2×12 or an engineered LVL with 2 jack studs per side.

How do you calculate the exact cut length of a door or window header?

Header Cut Length = Rough Opening Width + (Number of Jack Studs per Side × 1.5 inches × 2). For a 60" rough opening with 1 jack stud on each side, cut the header to 60" + 3" = 63". With 2 jack studs per side, cut to 66".

Do non-load-bearing interior walls need a structural double header?

No. Non-load-bearing partition walls only support drywall and interior door framing, so a single or double 2×4 flat header with 1 jack stud per side is typically sufficient.