1. Related Carpentry & Framing Tools
Estimate shelf sag with our Wood Shelf Sagulator, or plan exterior steps with the Concrete Steps Calculator.
THE TOOLBOX / FRAMING & STRUCTURES
Check midspan deflection, L/360 and L/240 stiffness limits, bending stress (psi), and post end-reactions for 1- to 4-ply 2×6, 2×8, 2×10, 2×12, and 2.0E LVL wood beams.
Preliminary Euler-Bernoulli estimate only (ignores shear, bearing length, and wet-service factors). Always verify load-bearing beams with local building codes or a licensed structural engineer.
STRUCTURAL PROPERTIES
| Beam Size | Actual Dimensions | Moment of Inertia (I) | Section Modulus (S) |
|---|---|---|---|
| 2×8 | 1.5" × 7.25" | 47.6 in⁴ | 13.1 in³ |
| 2×10 | 1.5" × 9.25" | 98.9 in⁴ | 21.4 in³ |
| 2×12 | 1.5" × 11.25" | 178.0 in⁴ | 31.6 in³ |
| LVL 1.75×11.875 | 1.75" × 11.875" | 244.2 in⁴ | 41.1 in³ |
Estimate shelf sag with our Wood Shelf Sagulator, or plan exterior steps with the Concrete Steps Calculator.
For a simply supported beam carrying a uniform distributed load, midspan deflection is δ = (5 × w × L⁴) ÷ (384 × E × I), where w is load in lbs/inch, L is span in inches, E is the wood’s modulus of elasticity (psi), and I = b·h³/12 is the moment of inertia.
L/360 means maximum midspan sag cannot exceed the span length divided by 360 (0.40 inches on a 12-foot span)—the standard residential code limit for live floor loads to prevent bounce and drywall cracking. L/240 is commonly used for total floor loads or roof rafters.
Moment of inertia scales with the cube of beam depth (h³). Stepping up from a 2×8 (7.25" deep) to a 2×12 (11.25" deep) increases stiffness by more than 3.7× for only 55% more lumber.
Switch to 2.0E LVL (Laminated Veneer Lumber) for spans over 12–14 feet or heavy load-bearing wall removals, because LVL offers roughly 25%–40% higher stiffness and more than double the bending strength of #2 framing lumber.
Multiply your tributary width (typically half the floor joist span supported by the beam) by total design PSF (standard residential floors use 40 psf live + 10 psf dead = 50 psf). For example, an 8-foot tributary width × 50 psf = 400 plf.
No. This is a preliminary sizing estimator. Always confirm load-bearing beams, bearing length, and shear capacity with your local building department or a licensed PE.