Guide

THE TOOLBOX / FRAMING & STRUCTURES

Wood Beam Load & Span Calculator —
Midspan Deflection (L/360), Bending Stress & LVL Sizing.

Check midspan deflection, L/360 and L/240 stiffness limits, bending stress (psi), and post end-reactions for 1- to 4-ply 2×6, 2×8, 2×10, 2×12, and 2.0E LVL wood beams.

Number of Plies
Deflection & Bending Stress (2-ply 2×10)
Deflection
0.52"
L / 279
Bending Stress
1767
psi (vs ~900 Fb)
Post Reaction
2,100
lbs per support
✕ Fails L/360✓ Passes L/240 (Roof/Total)✕ Over Fb Bending Limit

Preliminary Euler-Bernoulli estimate only (ignores shear, bearing length, and wet-service factors). Always verify load-bearing beams with local building codes or a licensed structural engineer.

STRUCTURAL PROPERTIES

Actual Dimensions & Moment of Inertia (Single Ply).

Beam SizeActual DimensionsMoment of Inertia (I)Section Modulus (S)
2×81.5" × 7.25"47.6 in⁴13.1 in³
2×101.5" × 9.25"98.9 in⁴21.4 in³
2×121.5" × 11.25"178.0 in⁴31.6 in³
LVL 1.75×11.8751.75" × 11.875"244.2 in⁴41.1 in³

Frequently Asked Questions

How is wood beam deflection calculated?

For a simply supported beam carrying a uniform distributed load, midspan deflection is δ = (5 × w × L⁴) ÷ (384 × E × I), where w is load in lbs/inch, L is span in inches, E is the wood’s modulus of elasticity (psi), and I = b·h³/12 is the moment of inertia.

What do L/360 and L/240 deflection limits mean?

L/360 means maximum midspan sag cannot exceed the span length divided by 360 (0.40 inches on a 12-foot span)—the standard residential code limit for live floor loads to prevent bounce and drywall cracking. L/240 is commonly used for total floor loads or roof rafters.

Why does beam depth matter so much more than width?

Moment of inertia scales with the cube of beam depth (h³). Stepping up from a 2×8 (7.25" deep) to a 2×12 (11.25" deep) increases stiffness by more than 3.7× for only 55% more lumber.

When should I upgrade from dimensional 2× lumber to an engineered LVL beam?

Switch to 2.0E LVL (Laminated Veneer Lumber) for spans over 12–14 feet or heavy load-bearing wall removals, because LVL offers roughly 25%–40% higher stiffness and more than double the bending strength of #2 framing lumber.

How do I estimate uniform load in lbs per linear foot (plf)?

Multiply your tributary width (typically half the floor joist span supported by the beam) by total design PSF (standard residential floors use 40 psf live + 10 psf dead = 50 psf). For example, an 8-foot tributary width × 50 psf = 400 plf.

Can I use this calculator to stamp structural plans?

No. This is a preliminary sizing estimator. Always confirm load-bearing beams, bearing length, and shear capacity with your local building department or a licensed PE.