Guide

THE TOOLBOX / HOME ENERGY & BUILDING

Insulation R-Value Calculator —
Wall/Attic R-Value Stack, U-Factor & Window Energy Payback.

Calculate combined insulation R-values by material and thickness, verify IECC climate-zone code targets, and estimate annual heating/cooling savings and payback for Low-E replacement windows.

IECC Climate Zone:

Recycled paper fiber, great for attic top-ups

12" (+R-42.0)
Total Effective Assembly R-Value
Total R-Value
R-55.2
incl. R-2.2 wall/film base
U-Factor (1/R)
0.018
BTU/hr·ft²·°F
Heat Loss Cut
−76%
conductive savings
Attic Target (R-60): Add R-5 moreWall Target (R-20): Meets IECC Code

R-VALUE PER INCH CHART

Common Residential Insulation Materials Compared.

MaterialR-Value / Inch2×4 Wall (3.5")2×6 Wall (5.5")
Fiberglass BattR-3.2 – R-3.7R-11 to R-15R-19 to R-21
Blown CelluloseR-3.5R-12.3R-19.3
Mineral Wool (Rockwool)R-4.0R-14 to R-15R-22 to R-23
Rigid XPS Foam BoardR-5.0R-17.5R-27.5
Closed-Cell Spray FoamR-6.5R-22.8R-35.8

Frequently Asked Questions

How do you calculate total insulation R-value?

Multiply each insulation material’s R-value per inch by its installed thickness in inches, then add all continuous layers together (including existing insulation and ~R-2.2 for drywall, sheathing, and interior/exterior air films). For example, 12 inches of blown-in cellulose (R-3.5/in) adds R-42 to an attic.

How do R-value and window U-factor relate to each other?

U-factor is the exact mathematical inverse of R-value: U = 1 / R (and R = 1 / U). Higher R-values mean better thermal resistance (used for walls and attics), while lower U-factors mean less heat transfer (used on NFRC window labels). A modern Low-E window with U-0.28 has an effective R-value of ~3.6.

What attic R-value is recommended by ENERGY STAR and IECC building codes?

ENERGY STAR and modern IECC codes generally recommend R-30 to R-38 in hot southern climates (Zones 1–2), R-49 in mixed climates (Zones 3–4), and R-49 to R-60 in cold northern climates (Zones 5–8).

Do replacement windows pay for themselves through energy bills alone?

Upgrading leaky single-pane windows (U-1.10) to double-pane Low-E argon windows (U-0.28) cuts window heat loss by ~75%, often paying back in 8–14 years in cold climates while dramatically improving comfort and draft control. Upgrading intact double-pane windows to triple-pane takes much longer on energy savings alone.

Which insulation gives the highest R-value per inch in tight walls?

Closed-cell spray polyurethane foam (~R-6.5/in) and foil-faced polyiso rigid board (~R-6.0/in) deliver the highest thermal resistance per inch, making them ideal for shallow 2×4 walls, rim joists, and cathedral ceilings.