Guide

THE TOOLBOX / LIFE & OFF-GRID POWER

Car Battery Inverter Calculator —
Runtime Hours, DC Amp Draw, Fuse Rating & Copper AWG Cable Sizing.

Calculate how long a 12V, 24V, or 48V Lead-Acid, AGM, or LiFePO4 battery bank will safely power any AC appliance through an inverter—plus exact DC amp draw, fuse rating, and cable gauge.

Safe Inverter Runtime & DC Wiring Sizing
Safe Runtime
1h 52m
660 Wh usable
DC Current Draw
29.4 A
353W DC input
Fuse & Cable
40A · 10 AWG
Est. RC: ~204 min

Handles vibration & deeper cycles better than starter batteries.

RELATED ELECTRICAL TOOLS

Power & Circuit Calculators.

Frequently Asked Questions

How long will a 100Ah 12V battery run a 300W load on an inverter?

A 12V 100Ah battery stores 1,200 Wh total. At 50% safe discharge (Lead-Acid/AGM) and 85% inverter efficiency, it runs a 300W AC load for ~1 hour 42 minutes. A LiFePO4 lithium battery (85% usable DoD) extends that to ~2 hours 53 minutes.

How do I size the DC fuse and cable for a 12V power inverter?

Calculate DC Amps = (AC Load Watts ÷ Inverter Efficiency) ÷ Battery Voltage. Multiply DC Amps by 1.25 for the inline fuse rating and select copper AWG cable thick enough to keep voltage drop under 3% over your cable run.