1. The Tetens Leaf VPD Formula
Saturation vapor pressure is computed as SVP(T) = 0.61078 × exp(17.27·T / (T + 237.3)). Leaf VPD equals SVP(T_leaf) − SVP(T_air) × (RH / 100).
THE TOOLBOX / GROWING & HORTICULTURE
Calculate exact Leaf VPD, Air VPD, and Dew Point in kPa from temperature, relative humidity, and leaf offset—then explore the interactive clickable VPD heatmap.
Right inside the 0.8–1.2 kPa sweet spot for healthy stomatal conductance and nutrient uptake.
| Temp \ RH | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% |
|---|---|---|---|---|---|---|---|---|---|
| 68°F | |||||||||
| 72°F | |||||||||
| 75°F | |||||||||
| 78°F | |||||||||
| 82°F | |||||||||
| 85°F |
VPD TARGETS BY GROWTH STAGE
| Growth Stage | Target Leaf VPD | Typical Temp / RH | Plant Physiology Goal |
|---|---|---|---|
| Clones & Seedlings | 0.4 – 0.8 kPa | 75–78°F · 70–80% | Minimize water loss while roots establish |
| Vegetative Growth | 0.8 – 1.2 kPa | 75–82°F · 55–68% | Rapid transpiration, CO₂ intake, and leaf expansion |
| Early–Mid Flower | 1.0 – 1.4 kPa | 74–80°F · 48–58% | Strong nutrient flow while keeping mold risk low |
| Late Flower / Ripening | 1.2 – 1.6 kPa | 70–77°F · 40–50% | Protect dense flowers from condensation and mildew |
Saturation vapor pressure is computed as SVP(T) = 0.61078 × exp(17.27·T / (T + 237.3)). Leaf VPD equals SVP(T_leaf) − SVP(T_air) × (RH / 100).
Always keep lights-off canopy temperature at least 5°F (3°C) above the dew point to prevent moisture beads on leaves.
Lay out raised beds or orchards with our Plant Spacing Calculator, or check outdoor comfort in the Heat Index & Wind Chill Calculator.
Vapor Pressure Deficit (VPD) measures the difference in kilopascals (kPa) between the moisture pressure inside a saturated plant leaf and the moisture pressure of the surrounding air. It is the primary driving force behind plant transpiration and root nutrient uptake.
Because leaves transpire water, leaf surface temperature under modern LED grow lights is typically 2°F to 3°F (1°C–1.5°C) cooler than ambient room air. Calculating VPD from leaf temperature gives a far more accurate measure of what the plant actually experiences.
Aim for 0.4–0.8 kPa during cloning and early seedling stages, 0.8–1.2 kPa during vigorous vegetative growth, 1.0–1.4 kPa in early-to-mid flowering, and 1.2–1.6 kPa during late flowering to reduce bud rot and powdery mildew risk.
Very low VPD (<0.4 kPa) slows transpiration, stalls calcium transport, and invites fungal pathogens. Very high VPD (>1.6 kPa) causes plants to close stomata to conserve water, leading to crispy leaf edges, nutrient burn, and stunted growth.
Point an inexpensive handheld infrared (IR) thermometer at the upper canopy leaves directly under your lights and compare that reading to your ambient tent hygrometer.
When lights turn off and night temperatures drop to or below the dew point, liquid condensation forms on leaves and buds—the fastest trigger for Botrytis (gray mold).