Guide

THE TOOLBOX / SOLAR & ENERGY

Solar Panel Calculator
for array sizing, battery bank, inverter & MPPT.

Size your solar panel array, LiFePO4 or AGM battery bank (12V/24V/48V), pure sine inverter, and MPPT charge controller from your daily kWh usage and local peak sun hours—100% privately.

Solar Array, Battery Bank & Inverter Sizer
Presets:
Quick-add appliance to daily load:
Solar Panels Needed
6 × 400W
2.40 kW array · ~129 sq ft
Battery Bank Size
20.5 kWh
426 Ah @ 48V (5× 100Ah)
Inverter Size (1.25×)
3,500 W
Pure sine wave continuous
MPPT Controller
63 A
Minimum charge rating @ 48V
Estimated Annual Production: 3,232 kWh/year
Monthly Equivalent Bill Offset: ~269 kWh/month
Depth of Discharge Factor: 85% usable capacity (LiFePO4)

SOLAR SIZING FORMULAS

How to size solar panels, batteries, and controllers accurately

1. Solar Array Wattage

Array Watts = Daily Wh ÷ (Peak Sun Hours × System Efficiency). Use ~80%–85% efficiency to account for panel heat derating, wiring losses, and MPPT conversion.

2. Battery Bank Capacity (kWh & Ah)

Battery kWh = (Daily kWh × Autonomy Days) ÷ (0.92 × DoD), then divide watt-hours by your system voltage (12V, 24V, or 48V) to get Amp-hours (Ah).

3. Inverter Headroom

Size your continuous pure sine wave inverter to at least 1.25× your peak simultaneous wattage so refrigerator compressors, pumps, and microwaves start smoothly without tripping overload protection.

4. MPPT Charge Controller Amps

Controller Amps = (Total Array Watts ÷ Battery Voltage) × 1.25. Moving from 12V to 48V cuts required amperage by 75%.

Related Energy & Home Tools

Auditing household power consumption? Pair this with our Electricity Cost Calculator or Unit Converter.

Frequently Asked Questions

How many solar panels do I need for my daily kWh usage?

Divide your daily watt-hours by (Peak Sun Hours × System Efficiency). For example, an 8 kWh/day (8,000 Wh) load with 4.5 peak sun hours and 82% efficiency requires 8,000 ÷ (4.5 × 0.82) ≈ 2,168 W—or six 400 W solar panels.

What are Peak Sun Hours?

Peak Sun Hours measure the equivalent number of hours per day when solar irradiance averages 1,000 W/m²—not total daylight hours. Most US and temperate regions average 3.5 to 5.5 peak sun hours/day (higher in sunny deserts, lower in cloudy northern winters).

Why does LiFePO4 need a smaller battery bank than AGM or lead-acid?

Lead-acid and AGM batteries should typically only be discharged to 50% Depth of Discharge (DoD) to preserve cycle life, whereas LiFePO4 lithium iron phosphate batteries safely deliver 80%–90% usable capacity—cutting total required battery kWh and weight nearly in half.

Should I pick a 12V, 24V, or 48V solar battery bank?

Use 12V for small camper vans under ~1,500 W inverter loads, 24V for medium cabins up to ~3,000 W, and 48V for whole-home or heavy off-grid systems above 3,000 W to minimize cable thickness, current (amps), and MPPT controller costs.

How is the MPPT charge controller amp rating calculated?

Divide total solar array watts by battery bank voltage and multiply by a 1.25 safety factor: MPPT Amps = (Array Watts ÷ Battery Volts) × 1.25.