Generator Wattage Load Calculator —
Running Watts, Motor Surge & Transfer Switch Sizer.

Build your home backup load list with one-click storm presets, calculate total running watts and peak motor starting surge, size a 30A or 50A transfer switch, and estimate fuel runtime.

Total Running Load

2,920 W

5 active appliances

Peak Starting Surge

4,470 W

+1,550 W largest motor surge

Recommended Size

3,750 W

5,000 W surge (20% headroom)

Transfer Switch & Fuel

L14-30P (30A)

~9.9 hrs (0.66 gal/hr)

Generator Capacity Utilization (Running vs Recommended)78% load

Recommended transfer switch: 30A (240V — max 7,200W) (6–10 circuits).

Appliance Load Checklist

Refrigerator / Freezer

Kitchen · 700 W run / 2,200 W start

1

Chest / Deep Freezer

Kitchen · 350 W run / 1,200 W start

0

Gas Furnace Blower (1/2 HP)

HVAC & Water · 800 W run / 2,350 W start

1

Sump Pump (1/2 HP)

HVAC & Water · 1,050 W run / 2,150 W start

1

Submersible Well Pump (1 HP)

HVAC & Water · 1,500 W run / 4,000 W start

0

Central AC (3-Ton)

HVAC & Water · 3,500 W run / 7,500 W start

0

Microwave Oven (1000W)

Kitchen · 1,200 W run / 1,200 W start

0

Wi-Fi Router, Modem & Laptops

Electronics · 250 W run / 250 W start

1

LED Home Lighting (10 Bulbs)

Home · 120 W run / 120 W start

1

Portable Space Heater

HVAC & Water · 1,500 W run / 1,500 W start

0

Electric Water Heater

HVAC & Water · 4,500 W run / 4,500 W start

0

Add Custom Appliance

Fuel & Safety Margin

GENERATOR SIZING GUIDE

Frequently Asked Questions

What is the difference between running watts and starting watts on a generator?

Running (rated) watts are the continuous power an appliance consumes while operating. Starting (surge) watts are the brief 2–3 second power spike required by electric motors in refrigerators, sump pumps, well pumps, and air conditioners when they first kick on.

Do I add all starting watts together when sizing a home generator?

Usually no. Unless two large motors start at the exact same millisecond, standard sizing adds all simultaneous running watts plus the single largest additional starting surge, then adds a 20% safety buffer for longevity and cleaner power.

When do I need a 30-amp vs. 50-amp generator transfer switch?

A 30-amp 240V transfer switch (L14-30 inlet) supports up to 7,200 running watts and typically powers 6 to 10 essential circuits. If your backup load exceeds 7,200W—such as running central AC or an electric water heater—step up to a 50-amp transfer switch or panel interlock.