Fireplace Mantel, Hearth & Wood Stove Clearance Checker

Verify baseline IRC R1001 fireplace mantel and hearth extension rules—plus NFPA 211 wood stove wall clearances—before building your surround or hearth pad.

ADJUST NEEDED — Below Baseline ClearanceFirebox opening area: 7.00 sq ft
Mantel Clearance Above Firebox Opening
Code minimum: ≥ 14" (for 8" mantel depth)
Yours: 14"PASS
Non-Combustible Hearth Extension (Front)
Code minimum: ≥ 20" (opening ≥ 6 sq ft)
Yours: 20"PASS
Hearth Extension Beyond Each Side
Code minimum: ≥ 12" each side
Yours: 10"TOO CLOSE

Note: For UL-listed factory-built fireplaces or EPA wood stoves, always follow the manufacturer's installation manual and local building inspector requirements, which take precedence over general IRC/NFPA tables.

IRC Masonry Fireplace Hearth Minimums

Related Home Heating & Remodeling Tools

Frequently Asked Questions

How far must a wood mantel be above a fireplace opening?

Under IRC Section R1001.11, combustible trim projecting more than 1.5 inches from the face of a masonry fireplace must have at least 12 inches of clearance above the firebox opening, increasing further for deeper mantels. Non-combustible stone, steel, or concrete mantels can be mounted closer.

How far must a fireplace hearth extend in front of the firebox?

For masonry fireplaces with an opening under 6 square feet, the non-combustible hearth must extend at least 16 inches in front and 8 inches on each side. If the opening is 6 square feet or larger, IRC requires 20 inches in front and 12 inches on each side.

What is the standard wall clearance for an unlisted wood stove?

NFPA 211 requires 36 inches of clearance from an unlisted wood stove to combustible walls. Installing a properly ventilated non-combustible wall shield with a 1-inch open air gap can reduce required clearance by up to 66% (down to a 12-inch minimum).

Do factory-built gas or EPA wood stoves follow different rules?

Yes. Modern UL-listed stoves and gas inserts are tested to much tighter manufacturer-specific clearances (often 6–12 inches). Always verify against the exact UL listing label on the back of your unit.